Thermo King 20ft container reefer · Ashton, MD · 2026-11
Call (855) 450-1212Request reefer service["reefer not cooling","temperature not dropping","no reefer codes displayed"]
When a Thermo King container unit runs without displaying error codes but fails to pull down the temperature, the most common culprit is a low refrigerant charge caused by a small leak in the system. Other frequent causes include a restricted thermal expansion valve, iced-up evaporator coils blocking airflow, a slipping compressor drive belt, or a faulty return air temperature sensor giving inaccurate readings to the controller. A driver can safely perform a few quick initial checks before calling for help. Verify that the setpoint is set correctly and the unit is actually running in cool mode rather than defrost or heat. Check the evaporator and condenser coils for physical blockages or heavy ice buildup. Look through the sight glass on the receiver tank if accessible to see if there are continuous bubbles, which indicates low refrigerant. Check that the door seals are tight and cold air is not leaking out. If basic visual checks look fine and the box temperature refuses to drop, you need a mobile reefer technician with manifold gauges to check operating pressures, perform leak detection, and safely recharge the refrigerant system.
Cause not confirmed on the call
unknown
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
When a Carrier reefer unit starts up, begins cooling, and then shuts down with code A00012, the safety system is triggering due to high coolant temperature to protect the reefer engine and compressor from severe damage. The most common cause is a thermal cool…
When a Carrier reefer unit shuts down and displays fault code A00018, it indicates a low refrigerant condition along with a low suction temperature or pressure fault. The primary cause is typically a refrigerant leak in the system, such as a cracked line, lea…
A clicking or metallic chattering noise coming from your Thermal King reefer belt area usually points to a failing belt tensioner pulley, a worn belt, or an accessory bearing starting to fail. When a belt tensioner spring or internal bearing breaks down, the …
When a Carrier reefer unit displays a B3 fuse error alongside a failure-to-start alarm while the control panel still powers up, the unit's control board is receiving logic power but detecting an open circuit on a specific protection loop or fuse trace. On Car…
Real breakdown calls to our 24/7 dispatch, written up without names or prices. Updated every hour.
Real calls coming in to our 24/7 dispatch right now. Names, companies and phone numbers are never shown.
All live requests and real calls →
Customer: My reefer unit has low voltage and won't run properly on I-15 near Littlefield, Arizona. Can someone meet me at the TA?
MTS: Yes, pull into the TA in Littlefield. We can dispatch a mobile technician to meet you there with a replacement battery and test the system.
Customer: What if it turns out to be the alternator instead of just a bad battery?
MTS: Our technicians diagnose and repair complete reefer electrical systems, including batteries, alternators, and charging systems for both Thermo King and Carrier units.
Customer: How long will it take for a service technician to reach me at the truck stop?
MTS: We can typically have a technician on-site at the TA within the hour once we set up your service order.
Run a truck repair, tire, towing or trailer business? Get listed free on Truck Repair Directory.