Thermo King reefer · Sault Ste. Marie, ON · 2026-11
Call (855) 450-1212Request reefer service["Thermo King error code 86","Thermo King error code 87","reefer not cooling","pressure sensor going off"]
Thermo King alarm codes 86 and 87 typically point to issues within the discharge and suction pressure sensor circuits or extreme pressure readings. Code 86 indicates a discharge pressure sensor check or high discharge pressure alarm, while code 87 relates to the suction pressure sensor circuit or abnormal suction pressure. When these codes trigger simultaneously, the control board disables the compressor to protect the system, preventing the reefer from cooling. Before calling for service, inspect the wire harness connected to the pressure transducers on the compressor and discharge line for loose plugs, corrosion, or damaged wires. Check the condenser coil for severe dirt blockage, ice build-up, or debris restricting airflow, and ensure the condenser fan is spinning properly. If the wiring and airflow look fine, the problem is usually a failed pressure transducer, a damaged transducer wiring harness, or an actual severe refrigeration system fault such as a severe refrigerant leak or clogged expansion valve. Diagnostic computer software is required to read live transducer voltage and pressure readings to confirm whether the sensor failed or actual system pressure is out of spec.
Cause not confirmed on the call
customer declined
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
When a Carrier reefer unit on a straight truck repeatedly shuts down during pre-cooling, the unit's controller is likely triggering a safety shutdown. Common causes include clogged fuel filters causing fuel starvation, low engine oil pressure, low engine cool…
When a Carrier reefer unit starts up, begins cooling, and then shuts down with code A00012, the safety system is triggering due to high coolant temperature to protect the reefer engine and compressor from severe damage. The most common cause is a thermal cool…
When a Carrier reefer unit shuts down and displays fault code A00018, it indicates a low refrigerant condition along with a low suction temperature or pressure fault. The primary cause is typically a refrigerant leak in the system, such as a cracked line, lea…
A clicking or metallic chattering noise coming from your Thermal King reefer belt area usually points to a failing belt tensioner pulley, a worn belt, or an accessory bearing starting to fail. When a belt tensioner spring or internal bearing breaks down, the …
Real breakdown calls to our 24/7 dispatch, written up without names or prices. Updated every hour.
Real calls coming in to our 24/7 dispatch right now. Names, companies and phone numbers are never shown.
All live requests and real calls →
Customer: My reefer unit has low voltage and won't run properly on I-15 near Littlefield, Arizona. Can someone meet me at the TA?
MTS: Yes, pull into the TA in Littlefield. We can dispatch a mobile technician to meet you there with a replacement battery and test the system.
Customer: What if it turns out to be the alternator instead of just a bad battery?
MTS: Our technicians diagnose and repair complete reefer electrical systems, including batteries, alternators, and charging systems for both Thermo King and Carrier units.
Customer: How long will it take for a service technician to reach me at the truck stop?
MTS: We can typically have a technician on-site at the TA within the hour once we set up your service order.